Korehau Uta Whakawhiti Fuse Whakakotahi taputapu
Tauira me te Tikanga
Ambient Here
Te pāmahana taiao: Max.temp.+40 ℃;Min.temp.-15℃
Te haumākū o te taiao: Te haumākū pātahi ia rā ≤ 95%;Te haumākū āhua ia marama ≤ 90
Te teitei o te waahi ka eke te ratonga Whakawhiti ki te 1000m
Mo nga ahuatanga ratonga motuhake, me waea atu ki te kaihanga
Paerewa Tohutoro
GB3804-2004 Ngaohiko-Teitei ngaohiko tauutuutu-naianei mo te ngaohiko whakatau i runga ake i te 3.6kV me te tae atu ki te 40.5kV
GB16926-2009 Ngaohiko-Teitei-Ngaohiko tauutuutu-naianei nga pahekotanga whakawhiti-whakawhiti
GB/T11022-1999 Ko nga whakaritenga noa mo nga taputapu hiko teitei me nga paerewa hiko
Tawhā Hangarau Matua o te Whakawhiti
Ingoa | Waeine | Whakawhiti GPL-24/T630-20 | Whakakotahitanga Whakawhiti GPLR-24/T125-40 | |
Ngaohiko whakatau | kV | 24 | 24 | |
auau kua tohua | Hz | 50 | 50 | |
Kua whakatauhia o naianei | A | 630 | 125 (kia rite ki te whae) | |
Whakatauria Wewete taumata | 1min te kaha o te kaha te tu i te ngaohiko | kV | Ka tuwhera nga hononga kapeka me nga pakaru 65; Te wahanga ki te wahanga, te wahanga ki te whenua 65 | |
Ko te kaha o te uira ka mau te ngaohiko | kV | Te wahanga ki te wahanga, te wahanga ki te whenua 125 ; Ka tuwhera te 125 nga hononga kapeka me nga kai wehe | ||
I whakatauhia te naianei pakaru iahiko poto | kA | - | 40 | |
Uta kaha te pakaru o naianei | A | 630 | - | |
I whakatauhia te katinga katinga pakaru i naianei | A | 630 | - | |
Uta kaha te pakaru o naianei | A | 31.5 | - | |
Whakatauria te utu taura ka pakaru te naianei | A | 16 | 16 | |
Whakatauria ia iahiko poto hanga naianei (te tihi) | kA | 50 | 100 | |
I whakatauhia te wa poto ki te tu i naianei | kA | 20 | - | |
I whakatauhia te wa poto ka tu ki te roanga o naianei | S | 4 | - | |
Ko te tihi kua whakatauhia ka mau i te naianei | kA | 50 | - | |
Kua whakatauhia te tango-whakahaere o naianei | A | - | 3150 | |
Te parenga iahiko | μΩ | ≤150 | ≤250+ Fuse | |
Te mana motopaika | W | 90 | ||
Ko te neke me te whakapumautanga ka whakaaetia te abrasion te matotoru whakaemi | mm | 3 | ||
Whakakore i waenga i nga hoapaki tuwhera | mm | 12±1 | ||
Whakapā atu ki te katinga te wā tāwhana | ms | ≤2 | ||
3-waahanga tukutahi | ms | ≤2 | ||
Te tere kati toharite | m/s | 0.8±0.2 | ||
Toharite tere whakatuwheratanga | m/s | 1.3±0.2 | ||
Te manawanui o te miihini | Nga taima | 10000 |
Tawhā Hangarau Matua o Motor
Ingoa | Waeine | Tawhā |
Ngaohiko mahi kua whakatauhia | V | AC/DC 110/220 |
Whakatauhia te whakauru hiko | W | 80 |
Awhe ngaohiko pūnoa o te motika ka tohutohutia |
| 85% ~ 110% Ngaohiko mahi Whakatauhia |
Te wa utu | s | ≤15 |
Hangarau Matua o Coil
Ingoa | Waeine | Tawhā | |
Ngaohiko mahi kua whakatauhia | V | AC, DC110 | AC, DC220 |
Kua whakatauhia te mahi o naianei | A | ≤3 | ≤2 |
Awhe ngaohiko pūnoa o te pōkai tata |
| 85% ~ 110% Ngaohiko mahi Whakatauhia | |
Awhe ngaohiko noa o te takai haerenga |
| 65% ~ 120% Ngaohiko mahi Whakatauhia |
Te Hanga me te Mahi
Ko te momo whakakā GPL(R) kei roto i te tikanga whakahaere me nga ruuma whakaweto arc i mua-muri, ko tana ara iahiko whakahaere matua ko te hanganga tauira papa.Ko te ruuma arc-containuish ruuma kua whakatauhia i roto i te hanganga poupou poutū poutū i hanga i te epoxy resin e te hangarau APG, na reira me te tino pai anti-creepage Ko te hoahoa hanganga tino pai e whakaiti ana i te kohinga o te puehu i runga i te mata o te ruuma arc-titiro, e kore e taea e anake te aukati i te korehau tineia ruma i te awe o waho, engari ka taea hoki te whakarite ki te whakaatu āhua ātete tiketike ki te pānga ngaohiko ara i roto i te āhuarangi mahana-mākū taiao parahanga taimaha ranei.
Ko te punaha whakahaere o te puna kua whakaritea i roto i te waka rererangi ka taea te utu e te a-ringa, i te motuka ranei, ko te tikanga whakahaere kei roto i te pouaka rino kua mau ki mua o te ruuma arc-continguish.Kua wehea te pouaka ki nga waahi huihuinga e rima ma nga papa papaki e wha, kei roto i tenei waahi ko te waahanga utu, te waahanga ruku, te waahanga tuku me te aukati o te miihini motuhake.Ko te hanganga o te momo whakakā GPL(R) kua whakaritea te tikanga whakahaere me nga ruuma whakaweto pewa ki roto i te tahora o mua-muri whakauru ka pai te rite ki nga mahi whakahaere o te miihini whakahaere me nga mahi e hiahiatia ana mo te pakaru me te hanga i te ruuma tinei arc.Ano, ka taea te whakaiti i nga tikanga o waenga me te whakaiti i te haruru me te kaha i pau na reira ki te arahi i te mahinga o te GPL(R) tino pono.