Tohu Me Te Ita Pungao
Momo Whakaahuatanga
Momo | Tūemi | Tikanga whakaatu | Mana | Maukati kotahi | Maukati hoapā rua | Kōkuhu | Whaiaro | Ahu | Rahi tapahi | Pikitia | |
taki | whakapā | taki | |||||||||
Momo hanga | GPXN-Q | Pīhi-pāpā | - | 96×48×88 | 91×44 | 3 | |||||
GPXN-T | Pīhi-pāpā | 96×48×55 | 91×44 | 3 | |||||||
Swg. | GPXN1-Q | Tirohanga | - | - | 96×48×88 | 91×44 | 1 | ||||
GPXN1-T | Tirohanga | - | 96×48×55 | 91×44 | 1 | ||||||
GPXN4-Q | Pīhi-pāpā | - | - | 144×48×104 | 138×44 | 4 | |||||
GPXN4-T | Pīhi-pāpā | - | 144×48×104 | 138×44 | 4 | ||||||
GPXN5-Q | Pīhi-pāpā | - | - | 96×48×88 | 91×44 | 2 | |||||
GPXN5-T | Pīhi-pāpā | - | 96×48×55 | 91×44 | 2 | ||||||
Kotahi Insulator me 2 Tohu | GPXN4-Q/M | Pīhi-pāpā | - | - | 144×48×104 | 138×44 | 4 | ||||
GPXN4-T/M | Pīhi-pāpā | - | 144×48×104 | 138×44 | 4 | ||||||
GPXN4-T/Z | Pīhi-pāpā | 144×48×104 | 138×44 | 4 | |||||||
Momo Motuhake | GPXN1-Q/CS | Tirohanga | - | - | - | 96×48×88 | 91×44 | ||||
GPXNP1-Q/W | Tirohanga | - | - | - | 96×48×88 | 91×44 | 1 | ||||
GPXN-Q/LCS | Tirohanga | - | - | 96×48×88 | 91×44 | 3 |
Tohu Ngaohiko Ka whakamahia i roto i te Waenga Matua Mowhiti
Ka whakamahia te tohu ngaohiko me te insulator hei tohu i te ahua o te hiko o te hikohiko hiko.
Ka whakamahia te kaitirotiro ngaohiko tonu GPXN9-C me te tohu hei tohu i te ahua o te hiko.Ko te tawhiti o te kohao o te kapeka tirotiro hiko he 14mm, 19mm ranei.
Ko te GPXN-C te kaiwhakarite i te wahanga ka whakamahia me te tohu hei tohu i te ahua o te hiko o te hiko hiko teitei me te tirotiro i nga waahanga o nga taputapu hiko.
Taki-hiko: ka kuhu te kaiwhakarite wahanga ki roto i te papa whenua, ki era atu pito ranei o nga taputapu ngaohiko teitei.
Wāhanga-tirohia: whakauru te kaiwhakarite wahanga ki roto i te kapeka tirotiro hiko o nga taputapu ngaohiko teitei e rua, mena he kanapa te rama rama, e whakaatu ana ko te waahanga whakamatautau kei te toha hiko.
Tohu Turanga
Ka taea e te tohu tuunga te whakataurite i te tuunga whakahaere me te ahuatanga o nga taputapu whakawhiti penei i te whakawhiti me te ara iahiko i roto i te punaha hiko.Ka whakamahia nuitia i runga i nga momo papa tawai katoa o te rūma whakahaere pokapū me te paewhiri o te taputapu whakawhiti i te tipu hiko, te teihana hiko me te teihana whakawhiti.Ko tenei raupapa o nga tohu tohu he nui te pono, te whanui o te ngaohiko mahi me te roa o te oranga.Kei te waatea te DC me te AC mo te whakamahi.
Tawhā Hangarau
Ngaohiko whakatau | DC/AC 98V~242V |
Te kaha marama | >40 cd/㎡ |
Ko te kaha o te kaha te tu i te ngaohiko | 2kV/1min |
Te parenga whakaahuru | ≥100MΩ |
Te tohanga mana | ≤1W |
Te pāmahana whakahaere | -15℃ ki te +50℃ |
Te ora | >10 tau |
Whakaatu mahi | Ko nga ahuatanga mahi e tohuhia ana me te tae whero/matomato me nga whakairoiro (Hei kowhiringa a nga kaihoko) |
Ahu whakahuahua: | 37.5×37.5×62(mm) |
Rahi tapahi: | Φ25(mm) |
Tauira | Whakaahuatanga |
GPWZ25-K/2 | Tohu Turanga-Kaiwhanga-Waahi |
GPWZ25-E/1 | Tohu Turanga-Whakawhiti Whenua |
GPWZ25-B/2 | Taraka Tohu Turanga-Handling |
GPWZ25-B/1 | Tohu Turanga-Momotu |
GPWZ25-K/1 | Tohu Turanga-Turanga Turanga Whakawhiti |
Tūnga Tohu Mata GPAS-72
Ko te GPAS-72 rangatū tūnga tohu mata tango LED rite te puna marama, ki te iti te kohi pūngao, tiketike pono, te ora ratonga roa, me ētahi atu A ka taea te tono ki nga momo switchgears rite tūnga tohu mata ki te otinga hoahoa pūnaha rerekē.Na te maha o nga mahi o te tohu wahanga-ngaohiko, te raka, te mana mahana me te haumākū, te tohu tuunga o te kaata ringaringa, te tohu tohu ara iahiko, te tohu mana huri whenua, te tohu hiko rongoa.He pai te whiriwhiri ki te whakakapi i te tohu tuunga o te whenua whakawhiti kotahi.
Tawhā Hangarau
Ngaohiko whakatau | AC/DC 110V/220V |
Ka mau te kaha o te kaha | 2kV/min |
Te taiao mahi | -25 ℃ ki te 55 ℃, ≤90%RH |
Maramarama tohu tairitenga | >40cd/m2 |
Te oranga mahi | 10 tau |
Taumata tiaki | IP42 |
Ahu | 199x146x63mm |
Rahi tapahi | 177x121mm |
Tawhā HangarauGpj-3100 Rangatū Porohita Poto Me te Tohu Hapa o te Whenua
Ko te raupapa GPJ-3100 o te ara iahiko poto me te tohu he o te whenua kua hangaia mo te whakamatautau me te whakaatu i te waahi poto me te he o te whenua i te waa.Ka whakamahia ki te aro turuki i nga hikohiko i roto i te RMU, te raina o runga, te raina tohatoha taura hiko, te momo momo pouaka me etahi atu waahi rite.E ai ki te tohu whakaoho e whakaatuhia ana e te tohu, ka taea e nga kaimahi te tarai me te tapahi tere i te waahi he i te wa e pa ana te porowhita poto, te he o te whenua ranei i roto i te ara iahiko, na reira ka taea e te punaha te whakahoki mai i te mana mo te waahi kore-hape kia tere te whakaora i te waa me te pai ake.
Raraunga Hangarau
1. iaiahiko poto ohorere o naianei: 100A ki te 1000A wa roa 40ms
2. Whakatairanga o naianei ohorere: 20A,30A,40A,50A,60A±10% wa roa 40ms
3. Te awhe pāmahana: -25 ki te +70 ℃
4. Awhe haumākū: ≦95%
5. Te roa o te mata o te whenua: 4m
6. Whakahaere muka whatu roa 3.5m
7. Te tuku hiko: te pākahiko lithium 3.6V / 2.45Ah
8. Wā tautuhi-aunoa: 7s,2haora,4haora,8haora
9. Rere Putanga: 120 V AC 1A, 30V DC 2A
10. Te rahi o te kaiwhakahaere matua: 95x50x80mm
11. Te rahi o te poka tapahi : 91x44 mm
12.Te karaehe tiaki : Kaiwhakahaere Matua :IP40, Sensor:IP65